SHDM Series – Heatless Modular Desiccant Air Dryers

DRYERS - COMPRESSED AIR / DESICCANT COMPRESSED AIR DRYERS

SHDM Series Modular Desiccant Air Dryers are ideal for point of use, laboratories and confined areas. They provide a continuous supply of dry compressed air by automatically cycling the flow of air through two desiccant beds.

Compact and intuitive, Hankison’s SHDM Series Modular Desiccant Air Dryers feature robust communications, are CSA/UL approved, and CRN registered. As powerful as it is versatile, the SHDM Series was designed and proven to protect moisture-sensitive applications requiring low-pressure dew points by delivering dew points of  ISO 8573-1: 2010 Class 1 (-100°F, -70°C) and Class 2 (-40°C) with flow rates of 3 to 177 scfm (5m3/h to 300m3/h). The SHDM Series is a perfect solution for labs, hospitals, pharmaceutical manufacturing, and other high-tech installations that demand performance and reliability.  

Compressed air enters the dryer and is directed to Tower 1 by valve (A), and then to the dryer outlet through shuttle valve (B). A portion of the dried air is throttled to near atmospheric pressure by means of orifice (C). This extremely dry, low-pressure air flows through and regenerates the desiccant in Tower 2 and is exhausted through purge/repressurization valve (D) and exhaust muffler (E) to atmosphere. After a set time, the automatic solid state timer closes purge/repressurization valve (D) allowing Tower 2 to repressurize slowly. At the end of 2 minutes, valve (A) shifts and purge/ repressurization valve (D) reopens. The main air flow is now dried by Tower 2 while Tower 1 is being regenerated. 

hankison-hshd-schematic.jpg
ModelDIMENSIONSIN/OUT CONNECTIONSWEIGHT
HWDINMMINLBSKG
3 SHDM16.7424.29.4238.88.3210.83/8"21.89.9
9 SHDM32.4822.99.4238.88.3210.83/8"3515.9
15 SHDM42.21071.99.4238.88.3210.83/8"4620.9
24 SHDM38.1967.718.7474.914.3363.21/2"101.546.1
32 SHDM441117.618.7474.914.3363.23/4"121.254.9
41 SHDM51.91318.318.7474.914.3363.23/4"136.762
59 SHDM65.91673.918.7474.914.3363.21"180.882
88 SHDM73.71871.918.7474.914.3363.21"186.584.6
118 SHDM67.11704.321.1535.919.5495.31-1/2"352.7160
147 SHDM75190521.1535.919.5495.31-1/2"396.8180
177 SHDM75190521.1535.919.5495.31-1/2"396.8180

Features

Compact and intuitive, Hankison’s SHDM Series Modular Desiccant Air Dryers feature robust communications, are CSA/UL approved, and CRN registered. As powerful as it is versatile, the SHDM Series was designed and proven to protect moisture-sensitive applications requiring low-pressure dew points by delivering dew points of  ISO 8573-1: 2010 Class 1 (-100°F, -70°C) and Class 2 (-40°C) with flow rates of 3 to 177 scfm (5m3/h to 300m3/h). The SHDM Series is a perfect solution for labs, hospitals, pharmaceutical manufacturing, and other high-tech installations that demand performance and reliability.  

Theory of Operation

Compressed air enters the dryer and is directed to Tower 1 by valve (A), and then to the dryer outlet through shuttle valve (B). A portion of the dried air is throttled to near atmospheric pressure by means of orifice (C). This extremely dry, low-pressure air flows through and regenerates the desiccant in Tower 2 and is exhausted through purge/repressurization valve (D) and exhaust muffler (E) to atmosphere. After a set time, the automatic solid state timer closes purge/repressurization valve (D) allowing Tower 2 to repressurize slowly. At the end of 2 minutes, valve (A) shifts and purge/ repressurization valve (D) reopens. The main air flow is now dried by Tower 2 while Tower 1 is being regenerated. 

hankison-hshd-schematic.jpg

Specifications

ModelDIMENSIONSIN/OUT CONNECTIONSWEIGHT
HWDINMMINLBSKG
3 SHDM16.7424.29.4238.88.3210.83/8"21.89.9
9 SHDM32.4822.99.4238.88.3210.83/8"3515.9
15 SHDM42.21071.99.4238.88.3210.83/8"4620.9
24 SHDM38.1967.718.7474.914.3363.21/2"101.546.1
32 SHDM441117.618.7474.914.3363.23/4"121.254.9
41 SHDM51.91318.318.7474.914.3363.23/4"136.762
59 SHDM65.91673.918.7474.914.3363.21"180.882
88 SHDM73.71871.918.7474.914.3363.21"186.584.6
118 SHDM67.11704.321.1535.919.5495.31-1/2"352.7160
147 SHDM75190521.1535.919.5495.31-1/2"396.8180
177 SHDM75190521.1535.919.5495.31-1/2"396.8180